View NCCI for Chapter 4.13: Angles connected by one leg

Taken from BS EN 1993-1-8: 2005, Section 3: Connections made with bolts, rivets or pins

Tension resistance of angles in SCI P363 (AD 351)
This NCCI is based on a Steel Construction Institute (SCI) Advisory Desk Note. SCI has received a number of questions regarding the tension resistance tables provided in the 'Eurocode Blue Book' (SCI publication P363) for single angles connected through one leg by welding or bolting. This AD clarifies the basis of the values in P363.
Valid until:
Jan 2011
Created by:
SCI
Created on:
Jan 2011
BSI Approval:
Not reviewed by BSI